Professional 75 Ohm double shielded coaxial cable for broadband networks HFC/CATV signal distribution. This cable is manufactured according highest quality standards and has PE gas injected dielectric with a stable impedance and fulfils in all aspects screening class B requirements. Applicable for indoor and outdoor use.
Available packages and colors:
Available packages and colors:
| 5736 | Advanced digital coaxial cable RG-6, CCS, double shielded, class B, white, 50m roll | IDLH-CRG6O5-CDWO50-RON |
| 5737 | Advanced digital coaxial cable RG-6, CCS, double shielded, class B, black, 50m roll | IDLH-CRG6O5-CDBO50-RON |
| 5738 | Advanced digital coaxial cable RG-6, CCS, double shielded, class B, white, 100m box | IDLH-CRG6O5-CDW100-BON |
| 5739 | Advanced digital coaxial cable RG-6, CCS, double shielded, class B, black, 100m box | IDLH-CRG6O5-CDB100-BON |
| 5740 | Advanced digital coaxial cable RG-6, CCS, double shielded, class B, white, 250m plastic reel | IDLH-CRG6O5-CDW250-REN |
| 5741 | Advanced digital coaxial cable RG-6, CCS, double shielded, class B, black, 250m plastic reel | IDLH-CRG6O5-CDB250-REN |
| 5742 | Advanced digital coaxial cable RG-6, CCS, double shielded, class B, white, 305m plastic reel | IDLH-CRG6O5-CDW305-REN |
| 5743 | Advanced digital coaxial cable RG-6, CCS, double shielded, class B, black, 305m plastic reel | IDLH-CRG6O5-CDB305-REN |
| Technical specifications | |
|---|---|
| Screening class | B |
| Applicable |
indoor/outdoor |
| Inner conductor |
|
| Material |
CCS |
| Diameter ᴓ [mm] |
1.02 |
| Cladding conductivity [%] |
22 |
|
|
|
| Dielectric |
|
| Material |
PE gas injected |
| Diameter ᴓ [mm] |
4.6 |
|
|
|
| 1st shielding |
|
| Material |
Bonded Al/PET/Al |
| Overlap [%] | 18 |
|
|
|
| 2nd shielding (braid) |
|
| Material |
Al |
| Braid coverage [%] |
70 |
|
|
|
| 3rd shielding |
|
| Material |
- |
|
|
|
| Outer sheath |
|
| Material |
PVC |
| Sheath diameter ᴓ [mm] |
6.8 |
| Sheath colour |
white or black |
| RoHS complaint |
yes |
| Characteristics |
UV protected, fire retardant, footage marker every meter |
|
|
|
| Electrical data |
|
| Impedance [Ω] |
75 ±2 |
| Capacitance [pF/m] |
53 ±2 |
| Velocity rate [%] |
83 |
| DC resistance centre conductor [Ω/km] |
92 |
| DC resistance outer conductor [Ω/km] |
26 |
| Loop resistance [Ω/km] |
118 |
| Sheath insulation voltage [kv] |
3 |
|
|
|
| Attenuation [dB/100m] at 20⁰C @ |
|
| 5 MHz |
1.9 |
| 50 MHz |
4.9 |
| 100 MHz |
6.55 |
| 200 MHz |
10 |
| 300 MHz |
12 |
| 500 MHz |
15 |
| 800 MHz |
19 |
| 950 MHz |
21 |
| 1750 MHz |
29 |
| 2050 MHz |
31 |
| 2400 MHz |
33.7 |
| 3000 MHz |
38 |
|
|
|
| Structural return loss [dB] @ |
|
| 5 MHz ~ 470 MHz |
> 26 |
| > 470 MHz ~ 1000 MHz |
> 26 |
| > 1000 MHz ~ 2000 MHz |
> 22 |
| > 2000 MHz ~ 3000 MHz |
> 20 |
|
|
|
| Screening attenuation [dB] @ |
|
| 30 MHz ~ 1000 MHz |
≥ 90 |
| > 1000 MHz ~ 2000 MHz |
≥ 80 |
| > 2000 MHz ~ 3000 MHz |
≥ 70 |
|
|
|
| Transfer impedance [mΩ/m] @ |
|
| 10 MHz ~ 30 MHz |
≤ 15 |
|
|
|
| Sweep tested @ |
|
| 5 MHz ~ 3000 MHz |
yes |
|
|
|
| Mechanical data |
|
| Operating temperature |
-30⁰C ~ +70⁰C |
| Installation temperature |
-10⁰C ~ +50⁰C |
| Bending radius (single/multiple) [mm] |
35/70 |
| Tensile strength [N] |
120 |
| Weight approx. [kg/km] |
42 |
| Compliant according |
EN50117, IEC61196, Construction Product Regulations (CPR) |
| Footage markers per meter |
1 |
Images