Professional Redundancy ASI Switch
IDLV-2000AL
_0.jpg)
The IDLV-2000AL is an intelligent DVB ASI TS Master-Slave redundancy and backup system. It is equipped with up to six independent switching blocks, each with two ASI input ports – master and slave – and two ASI output ports (mirrored output). Each switching block is able to monitor in real time the TS Sync byte and up to eight user-specified PIDs carried in the master TS simultaneously. Under normal conditions, the output stream is the master TS itself. As soon as errors are detected during monitoring, the switching module will toggle to the Slave TS in milliseconds. Its fast switching and high reliability make the IDLV-2000AL a perfect broadcast redundancy system.
Main Features:
- Compact 1RU Chassis
- Fully compatible with DVB-ASI (EN50083) Standard
- Up to 6 Switch Blocks
- High Performance with Output Bit-Rates up to 160 Mbit/s per Switch Block
- ASI TS automatically or manually Switching
- Master ASI TS Passthrough directly when Power Off
- 12 VDC Power Supply Input Backup
- Service PID Monitoring on ASI Master Input
- Full Control and Monitoring via RS232 Interface
Product Specifications

| Operational Temperature Range | 0 °C ~ 40 °C |
| Power Supply | 90 ~ 265V AC |
| Power Consumption | 20 W |
| Inputs: | |
| Input Ports | 12 (6 Masters, 6 Slaves) |
| Input Interface | BNC, 75Ω |
| Input TS Bit Rate | 160 Mbits/s Max. |
| Packet Format (of Input TS) | 188 or 204 Byte Packets |
| Outputs: | |
| Number of Outputs | 12 (6 x 2 identical Outputs) |
| Output Interface | BNC, 75Ω |
| Output TS Bit Rate | 160 Mbits/s Max. |
| Packet Format (of Output TS) | 188 or 204 Byte Backets |
| General: | |
| Data Interface | RS232 (DB-9) for PC Setup and Software Upgrade |
| Alarm Relays | 6 |
| LCD | 2X10 cm LCD Display (green) |
| LED | 7 (1 for Power Indicator, 6 for TS Indicator) |
| Keypad | ‘<’、’^ ’、‘v’、’>’、‘Enter’and‘Exit’ |
| * Monitors ETR290 parameters of master ASI input | |
| * Programmable service monitoring | |
| * Programmable PID monitoring | |
| * Raises an alarm and switch to slave if the master TS fails | |
| * Raises an alarm and switch to slave if a particular service or a particular PID is missing in the master TS |

Product registration